2022.10.15
沈陽弱電工程的安裝流程及施工規范
前言:
220V50Hz及以下的統(tong)(tong)(tong)(tong)稱為(wei)(wei)弱電(dian),主(zhu)要向(xiang)人們(men)提供電(dian)力能源(yuan),將電(dian)能轉換為(wei)(wei)其他能源(yuan),例如空調(diao)用電(dian),照明用電(dian),動力用電(dian)等等。弱電(dian)系(xi)(xi)統(tong)(tong)(tong)(tong)范(fan)圍很廣,比較常見的有:保安(an)監控(kong)系(xi)(xi)統(tong)(tong)(tong)(tong)、消防報警系(xi)(xi)統(tong)(tong)(tong)(tong)、出入(ru)口控(kong)制系(xi)(xi)統(tong)(tong)(tong)(tong)、停車場收費管理系(xi)(xi)統(tong)(tong)(tong)(tong)和樓(lou)宇自控(kong)系(xi)(xi)統(tong)(tong)(tong)(tong)等等,今天來談(tan)談(tan)弱電(dian)工程的安(an)裝流程及施(shi)工規范(fan)。
一、 施工步驟:
1、勘察現場
A.與客(ke)戶(hu)協(xie)商,借用存放材料的(de)(de)(de)材料間,材料間要足夠(gou)大,且距離施工(gong)現(xian)(xian)場(chang)較近(jin)。B.水電(dian)(dian)設(she)備(bei)。現(xian)(xian)場(chang)是否具備(bei)施工(gong)必需的(de)(de)(de)水電(dian)(dian)設(she)施。 C.電(dian)(dian)力負(fu)荷。施工(gong)現(xian)(xian)場(chang)的(de)(de)(de)電(dian)(dian)力線是否能匹配工(gong)程的(de)(de)(de)負(fu)荷要求。D.設(she)備(bei)布局。確(que)(que)(que)定機柜的(de)(de)(de)位置、終端設(she)備(bei)的(de)(de)(de)安裝位置以及線路的(de)(de)(de)的(de)(de)(de)敷設(she)路逕(jing)。E.樣(yang)品(pin)式樣(yang)。明確(que)(que)(que)客(ke)戶(hu)的(de)(de)(de)要求,確(que)(que)(que)定樣(yang)品(pin)的(de)(de)(de)型號、樣(yang)式。要形成文(wen)檔,客(ke)戶(hu)簽字確(que)(que)(que)認。F.安全。原材料的(de)(de)(de)安全,施工(gong)現(xian)(xian)場(chang)的(de)(de)(de)防火防盜的(de)(de)(de)措施。
2、繪制網(wang)絡拓撲圖、布(bu)局圖,交客戶方(fang)確認(ren)。
3、制定(ding)工程(cheng)進度(du)計(ji)劃(hua)表(biao)。列(lie)舉施工期間(jian)需要完成的(de)工作任務(wu),以及各項工作完成的(de)先后(hou)次序,并確定(ding)詳細的(de)計(ji)劃(hua)時間(jian),如下圖所示。工程(cheng)進度(du)表(biao)完成后(hou)需交給(gei)客戶一份(fen),以備客戶監督(du)和配合。

4、指(zhi)定工程負責(ze)人和(he)工程監(jian)理(li)(li)人員,負責(ze)規劃備(bei)料,備(bei)工,用戶(hu)方配(pei)合要求等方面事宜(yi),提出各部門配(pei)合的時間表(biao),負責(ze)內外協(xie)調和(he)施工組織(zhi)和(he)管理(li)(li)
5、現場施(shi)工,每(mei)日記錄(lu)施(shi)工進度,并(bing)根(gen)據計(ji)(ji)劃的完成情況及時調整(zheng)計(ji)(ji)劃,確保按工期工要求交(jiao)付工程。
6、現(xian)場(chang)認證測試,制作測試報(bao)告,打印IP地址(zhi)表、路由表、配置表。
7、驗收(shou)(shou)。在上述(shu)各(ge)環節中所建立和完善的文(wen)檔,作(zuo)為(wei)驗收(shou)(shou)資(zi)料的一部分,交客戶(hu)保(bao)存。同(tong)時公司(si)也要(yao)留存幅(fu)本,作(zuo)為(wei)客戶(hu)資(zi)料,以備(bei)售(shou)后服(fu)務用(yong)。
二、布局規范:
布(bu)局(ju)是后續工作的(de)基礎,所(suo)以一定要事先確(que)定下來(lai),否(fou)則(ze)一旦返(fan)工,代價極(ji)高。電腦桌的(de)高度規范:小學約70CM,中學約75CM; 座位尺(chi)寸(cun)規范:寬(kuan)60—80CM,前后約60CM;排與(yu)排之間(jian)(jian)、列(lie)與(yu)列(lie)之間(jian)(jian)的(de)走道(dao)預留寬(kuan)度:60—100CM;布(bu)局(ju)圖(tu)必段根據場地(di)(di)、設施實(shi)際(ji)盡尺(chi)寸(cun),按比例繪制,圖(tu)中要標明詳細尺(chi)寸(cun)。確(que)定好布(bu)局(ju)圖(tu)要給客戶簽字(zi)確(que)認(ren),必要時可(ke)在(zai)場地(di)(di)上勾描出布(bu)局(ju)的(de)輪廓(kuo)以獲得直觀感受。
三、布線(xian)(xian)規范(網線(xian)(xian)、電源(yuan)線(xian)(xian))
1、電(dian)纜標志內(nei)容:在電(dian)纜的(de)護(hu)套上約以1M的(de)間隔標明(ming)生(sheng)產(chan)廠廠名或代號(hao)及電(dian)纜型號(hao)規格,制造(zao)年份,電(dian)纜長(chang)度。
2、塑料線(xian)槽(cao)及(ji)其(qi)附件型號規(gui)格應符合(he)設(she)計要求,并選用(yong)相(xiang)應的定型產品。其(qi)敷設(she)場所的環境溫度(du)不(bu)得低(di)于-15攝氏度(du),其(qi)阻燃性能氧(yang)指數不(bu)應低(di)于27%。線(xian)槽(cao)內外應光滑無棱刺,不(bu)應有有扭(niu)曲、翹邊等變(bian)形(xing)現(xian)象,并有產品合(he)格證。
3、纜線(xian)布放(fang)時(shi)應有冗余。在機柜處,雙絞線(xian)纜預(yu)留(liu)長(chang)度(du),一般為3~6m;終端處為0.3~0.6m;光纜在設(she)備端預(yu)留(liu)長(chang)度(du)一般為5~10m;有特殊要求的應按(an)設(she)計要求預(yu)留(liu)長(chang)度(du)
4、設備間鋪(pu)設活(huo)動地板(ban)(ban)時,板(ban)(ban)塊鋪(pu)設嚴(yan)密(mi)堅固,每(mei)平方(fang)米水平允許偏(pian)差不應大于(yu)2mm,地板(ban)(ban)支柱(zhu)牢固,活(huo)動地板(ban)(ban)防靜(jing)電措施(shi)的接地應符(fu)合(he)設計和產品(pin)說(shuo)明要(yao)求(qiu)。
5、每對(dui)對(dui)絞(jiao)線(xian)應盡量(liang)保持扭絞(jiao)狀態(tai),非扭絞(jiao)長度不應大于13mm。
6、剝(bo)除護套均不得刮傷(shang)絕(jue)緣(yuan)層,應使用專用工(gong)具剝(bo)除。
7、纜線中間不得產生接(jie)頭現象(xiang)。
8、雙絞線最長(chang)線距為100米,超過100 米的(de)可用雙絞線中(zhong)繼器連結加長(chang),每(mei)段線路中(zhong)中(zhong)繼器的(de)數(shu)據(ju)不能(neng)多于三個。
9、光纖(xian)傳(chuan)輸(shu)距離(li):傳(chuan)輸(shu)速率1Gb/s,850nm,、普(pu)通(tong)50μm多(duo)模(mo)光纖(xian)傳(chuan)輸(shu)距離(li)550m,普(pu)通(tong)62.5μm多(duo)模(mo)光纖(xian)傳(chuan)輸(shu)距離(li)275m,新型50μm多(duo)模(mo)光纖(xian)傳(chuan)輸(shu)距離(li)1100m。
10、纜(lan)線(xian)的(de)彎曲半徑應符合(he)下列規定:
a 非(fei)屏蔽(bi)4對雙絞(jiao)線纜(lan)的(de)彎曲半徑(jing)應(ying)至少(shao)為電纜(lan)外徑(jing)的(de)4倍(bei)在施工過程中(zhong)應(ying)至少(shao)為8倍(bei)。
b 屏蔽雙(shuang)絞線(xian)纜的彎(wan)曲半(ban)徑(jing)應至(zhi)少為(wei)電纜外徑(jing)的6~10倍。
c 主干(gan)雙絞線纜的(de)彎曲半徑應至少為電纜外徑的(de)10倍(bei)。
d 光(guang)纜的(de)彎曲半徑(jing)應(ying)至少為光(guang)纜外徑(jing)的(de)1.5倍,在施工過程中(zhong)應(ying)至少為20倍。
11、 對絞線在信息(xi)插座(RJ45)相連時(shi),必須按色標和(he)線對順(shun)序(xu)進行卡接。插座類(lei)型(xing),色標和(he)編號應符T568A、T568B的規(gui)定。如下圖所示(shi)。

12、在制作水晶(jing)頭(tou)(tou)時(shi),電(dian)纜(lan)(lan)的(de)(de)外(wai)保護層需要壓(ya)在接頭(tou)(tou)中而不能在接頭(tou)(tou)外(wai)。因(yin)為當電(dian)纜(lan)(lan)受到外(wai)界的(de)(de)拉(la)力時(shi)受力的(de)(de)是整個電(dian)纜(lan)(lan),否則(ze)受力的(de)(de)是電(dian)纜(lan)(lan)和(he)接頭(tou)(tou)連接的(de)(de)金(jin)屬部(bu)分(fen)。
13、雙(shuang)絞線纜與接(jie)線模塊(IDC,RJ45)卡接(jie)時,應(ying)按設計和廠家規定進行操作。
14、 屏(ping)(ping)蔽(bi)雙絞線纜的屏(ping)(ping)蔽(bi)層與接(jie)插件(jian)終(zhong)端處屏(ping)(ping)蔽(bi)罩可靠接(jie)觸,纜線屏(ping)(ping)蔽(bi)層應與接(jie)插件(jian)屏(ping)(ping)蔽(bi)罩360o圓周接(jie)觸,接(jie)觸長度不宜(yi)小(xiao)于100mm。
15、每股雙膠線兩端應(ying)粘膠標簽并編號,以(yi)便于安(an)裝(zhuang)和維護。

16、交接間(jian)、設(she)備間(jian)提供(gong)可靠的施工電源(yuan)和接地(di)裝置。
17、施(shi)工現場臨(lin)(lin)時(shi)電(dian)(dian)源(yuan)應有完整的(de)插頭.開關.插座.漏電(dian)(dian)保護器設置,臨(lin)(lin)時(shi)用電(dian)(dian)須(xu)用電(dian)(dian)纜。電(dian)(dian)源(yuan)線分三(san)種顏色(se)(se):火線紅色(se)(se).零(ling)線蘭色(se)(se).地線黃(huang)色(se)(se).所(suo)有單向插座應該“左零(ling)右火中(zhong)間地“或“上火下零(ling)“連接。
18、電源(yuan)線(xian)管從地(di)面(mian)下穿過(guo)時(shi)(shi),必(bi)須使用套管連接(jie)緊密(mi),在地(di)面(mian)下不允許有(you)接(jie)頭,出入地(di)面(mian)處必(bi)須套用彎頭。地(di)面(mian)沒有(you)封(feng)閉之(zhi)前(qian),必(bi)須保護(hu)好PVC套管,不允許有(you)破裂損(sun)傷,鋪地(di)板磚時(shi)(shi)PVC套管應(ying)被覆(fu)蓋(gai),釘木地(di)板時(shi)(shi),電源(yuan)線(xian)應(ying)沿墻角鋪設,以防止電源(yuan)線(xian)被釘子損(sun)傷。
19、 電源線走向橫平豎直,不可斜(xie)拉,防止(zhi)被電錘.釘子損傷。
20、各(ge)種強(qiang)弱電插座接口要盡量少。 所(suo)有插座.開(kai)關要高于地面(mian)300MM以上,并且(qie)不(bu)會被(bei)推(tui)拉門(men)家俱等物(wu)遮擋。
21、弱電線路與強(qiang)電線路不(bu)允許共套一管(guan),其間隔距離為0.5m以上。
22、三相五線(xian)(xian)(xian)(xian)制是指A、B、C、N和PE線(xian)(xian)(xian)(xian),其(qi)中,PE線(xian)(xian)(xian)(xian)是保護(hu)地線(xian)(xian)(xian)(xian),也叫(jiao)安全線(xian)(xian)(xian)(xian),是專門用(yong)于接到諸如設備外(wai)殼等保證用(yong)電安全之用(yong)的。應用(yong)中最(zui)好(hao)使用(yong)標(biao)準/規范的導(dao)線(xian)(xian)(xian)(xian)顏色(se):A線(xian)(xian)(xian)(xian)用(yong)黃色(se),B線(xian)(xian)(xian)(xian)用(yong)藍色(se),C線(xian)(xian)(xian)(xian)用(yong)紅(hong)色(se),N線(xian)(xian)(xian)(xian)用(yong)褐(he)色(se),PE線(xian)(xian)(xian)(xian)用(yong)黃綠色(se)。
23、工程中各板塊之間的電源(yuan)要盡(jin)量分開(kai)控(kong)制,盡(jin)量做到(dao)獨立供電,互(hu)不干憂(you)。
四、設備安裝與調試
1、機柜安放位置的選擇規范(fan)
A .安全性。隱蔽(bi),通風(feng),最(zui)好有(you)專(zhuan)用間,進出有(you)限制。B.可靠性。有(you)合適的(de)電源接入點,有(you)足夠的(de)電力保(bao)障,維護方便。C.可用性。到各終端的(de)線(xian)距(ju)在(zai)規范要求的(de)范圍以內。D.經濟(ji)性。到終端線(xian)距(ju)總(zong)量(liang)最(zui)小(xiao)。
2、網絡設備的安(an)裝(zhuang)規(gui)范
A.網(wang)絡設備(路(lu)由器、交換機(ji)等(deng))應安裝在固(gu)(gu)定的(de)(de)托架(jia)上;B.固(gu)(gu)定的(de)(de)托架(jia)一般應距地面500mm以上;C.插(cha)入網(wang)絡設備的(de)(de)電(dian)纜(lan)線要固(gu)(gu)定在托架(jia)或墻上,防(fang)止意 外脫(tuo)落(luo)。
3、終端設(she)備(bei)安裝(zhuang)步驟
A.首先(xian)閱讀設備(bei)(bei)手冊和設備(bei)(bei)安裝說明(ming)書。B.設備(bei)(bei)開(kai)箱(xiang)要(yao)按裝箱(xiang)單進行(xing)(xing)清點,對設備(bei)(bei)外(wai)觀進行(xing)(xing)檢(jian)查(cha),認(ren)真詳細地做好記錄(lu)。C.設備(bei)(bei)就位。D.逐臺(tai)設備(bei)(bei)分別進行(xing)(xing)加(jia)電,做好自檢(jian)。E.逐臺(tai)設備(bei)(bei)分別聯到服(fu)務器上(shang),進行(xing)(xing)聯機(ji)檢(jian)查(cha),出(chu)現問題(ti)應逐一解決。有(you)故障的設備(bei)(bei)留(liu)在(zai)最后解決。F.安裝系(xi)(xi)統(tong)(tong)軟件(jian),進行(xing)(xing)主系(xi)(xi)統(tong)(tong)的聯調工(gong)作。G.安裝各工(gong)作站(zhan)軟件(jian),各工(gong)作站(zhan)可正常上(shang)網工(gong)作。H.逐個解決遺留(liu)的所有(you)問題(ti)。I.用(yong)戶按操作規(gui)程可任意(yi)上(shang)機(ji)檢(jian)查(cha),熟悉(xi)網絡系(xi)(xi)統(tong)(tong)的 各種(zhong)功能。J.試運行(xing)(xing)開(kai)始。
五(wu)、弱電工程故(gu)障排查規范
1、根據(ju)統計(ji),弱電(dian)(dian)工(gong)程故(gu)障(zhang)(zhang)大約50%一70%與(yu)電(dian)(dian)纜有關系。所以(yi)電(dian)(dian)纜本身的質量(liang)以(yi)及安裝質量(liang)都(dou)直接(jie)影響網絡的正常運行。網絡電(dian)(dian)纜故(gu)障(zhang)(zhang)有很多(duo)種,概括(kuo)起來(lai)可以(yi)分為物理故(gu)障(zhang)(zhang)(也可稱連接(jie)故(gu)障(zhang)(zhang))和電(dian)(dian)氣性(xing)能故(gu)障(zhang)(zhang)兩大類。
A.物(wu)理故(gu)障。物(wu)理故(gu)障主(zhu)要是指(zhi)由于(yu)主(zhu)觀因素造成(cheng)的(de)(de)(de)可以直(zhi)接觀察的(de)(de)(de)故(gu)障,多是由于(yu)施工的(de)(de)(de)工藝或(huo)對網(wang)絡電纜的(de)(de)(de)意外損(sun)傷所造成(cheng)的(de)(de)(de),如(ru):模塊、接頭的(de)(de)(de)線序錯誤(wu),鏈路的(de)(de)(de)開路、短(duan)路、超長等。
B.電(dian)氣性能故障(zhang)(zhang)。電(dian)氣性能故障(zhang)(zhang)主要是指鏈路的(de)電(dian)氣性能指標未(wei)達(da)(da)到測試標準(zhun)的(de)要求(qiu),即電(dian)纜(lan)在信(xin)號傳輸過(guo)程中(zhong)(zhong)達(da)(da)不到設計要求(qiu)。影響電(dian)氣性能因素除電(dian)纜(lan)材料本身的(de)質(zhi)量外(wai),還包(bao)括施工過(guo)程中(zhong)(zhong)電(dian)纜(lan)的(de)過(guo)度彎曲、電(dian)纜(lan)捆綁太緊(jin)、過(guo)力拉(la)伸(shen)和(he)過(guo)度靠近干(gan)擾(rao)源等,如:近端串(chuan)擾(rao)、衰減、回(hui)波損耗等。
2、綜合布線的故障(zhang)多在水平區。這里穿線和(he)模塊端(duan)接較多,施工工藝因人(ren)而異,建筑格局比(bi)垂直部分復雜(za)。總體來(lai)說引起(qi)故障(zhang)有3方面。
A.產(chan)品(pin)本身(shen)的(de)(de)電氣性能,即產(chan)品(pin)的(de)(de)設(she)(she)計與(yu)生產(chan)質量(liang)。B.工程方案的(de)(de)設(she)(she)計,根據建筑格局,對布(bu)線系(xi)統的(de)(de)設(she)(she)計要求。C.施工工藝,這(zhe)是布(bu)線整(zheng)體(ti)質量(liang)的(de)(de)體(ti)現,好的(de)(de)產(chan)品(pin)和好的(de)(de)施工方案,都(dou)要有好的(de)(de)施工完成。
3、打線的(de)(de)常(chang)見錯誤(wu)(wu)。打線的(de)(de)常(chang)見錯誤(wu)(wu)有開路(lu),短(duan)路(lu),反(fan)接(jie)(一對線中的(de)(de)兩根交叉了,如1對應(ying)2,2對應(ying)1)。另外一個錯誤(wu)(wu)是跨(kua)(kua)接(jie),如1、2對應(ying)3、6。造成這種錯誤(wu)(wu)的(de)(de)原因主要(yao)有兩個。一是電纜(lan)的(de)(de)一端(duan)使(shi)用(yong)(yong)(yong)了T568A標準,而電纜(lan)的(de)(de)另一端(duan)使(shi)用(yong)(yong)(yong)了T568B標準。二(er)是在網絡的(de)(de)實際應(ying)用(yong)(yong)(yong)中,有時(shi)需(xu)要(yao)使(shi)用(yong)(yong)(yong)這種跨(kua)(kua)接(jie)線。當有的(de)(de)交換機(ji)(ji)與交換機(ji)(ji)進行(xing)級連時(shi)就需(xu)要(yao)使(shi)用(yong)(yong)(yong)跨(kua)(kua)接(jie)線。
另外當把PC機和(he)PC機進行對接(jie)時(shi)(不通過交(jiao)換機),也需(xu)要使(shi)(shi)(shi)用跨接(jie)線。有的(de)用戶(hu)使(shi)(shi)(shi)用了跨接(jie)線時(shi)也可以(yi)上網,而使(shi)(shi)(shi)用正確(que)接(jie)線時(shi)也能進行交(jiao)換機的(de)級連。這是(shi)因為他(ta)們使(shi)(shi)(shi)用的(de)交(jiao)換機是(shi)智能交(jiao)換機。這種交(jiao)換機可以(yi)自動將接(jie)線的(de)繞對對調過來。但這不代表這種打線的(de)方式是(shi)正確(que)的(de)。
最后(hou)還(huan)有一(yi)種(zhong)錯(cuo)誤就是(shi)(shi)(shi)串(chuan)繞。通常造成(cheng)這(zhe)(zhe)種(zhong)結(jie)果的(de)(de)(de)原因是(shi)(shi)(shi)1、2為一(yi)對,3、4為一(yi)對,5、6為一(yi)對,7、8 為一(yi)對。而(er)網絡(luo)(luo)進行通訊時(shi)使用(yong)1、2和3、6,而(er)不是(shi)(shi)(shi)3、4。這(zhe)(zhe)種(zhong)錯(cuo)誤的(de)(de)(de)接線是(shi)(shi)(shi)無(wu)法用(yong)眼睛或萬用(yong)表來(lai)(lai)檢查(cha)出(chu)來(lai)(lai)的(de)(de)(de),因為其端(duan)至端(duan)的(de)(de)(de)連通性是(shi)(shi)(shi)正常的(de)(de)(de)。而(er)這(zhe)(zhe)種(zhong)錯(cuo)誤接線的(de)(de)(de)最大(da)危害(hai)是(shi)(shi)(shi)會產生很大(da)的(de)(de)(de)近端(duan)串(chuan)擾。它(ta)不會造成(cheng)網絡(luo)(luo)不通,而(er)是(shi)(shi)(shi)使網絡(luo)(luo)運(yun)行速度很慢(man),時(shi)通時(shi)斷。它(ta)屬(shu)于軟故障(zhang),當網絡(luo)(luo)運(yun)行后(hou)檢查(cha)起來(lai)(lai)很麻煩。